Type I diabetes mellitus (DM1) is a complex disease with adverse effects on organs and tissues despite compensation by insulin treatment. The goal of our study was to study how kidney diseases change 31P MR parameters of muscle metabolism in DM1 patients with respect to gender. 51 DM1 patients (19 m/14 f without and 13 m/5 f with nephropathy) and 26 (14 m/12 f) healthy volunteers were examined using 31P magnetic resonance spectroscopy at 3T tomograph at rest, and during and after a calf muscle exercise. The exercise consisted of a six-minute plantar flexion using a pedal ergometer followed by a six-minute recovery. It is reflected by reduced relative β-ATP and increased Pi and phosphodiester signals to phosphocreatine (PCr) at rest and prolongation of the PCr recovery time after the exercise. Measurement on healthy volunteers indicated differences between males and females in pH at the rest and after the exercise only. These differences between patients groups were not significant. We have proven that nephropathy affects the metabolism in diabetic patients and our results confirm significant difference between patients with and without nephropathy. Gender differences in pH were observed only between male and female healthy volunteers., P. Sedivy, M. Dezortova, M. Drobny, Z. Vlasakova, V. Herynek, M. Hajek., and Obsahuje bibliografii
To determine whether acutely-induced supraphysiological hyperinsulinemia influences brain metabolism in patients with type 1 diabetes (D) and healthy controls (C) as detected by MR Spectroscopy. Group D consisted of 4 patients with the average duration of diabetes for 7 years. They were matched according to age, sex and BMI to 4 healthy controls. 1H MR Spectroscopy was performed with a 1.5 Tesla. Spectra were obtained from parietooccipital white matter repeatedly during a 3-h hyperinsulinemic euglycemic clamp with 2 mU.kg-1.min-1. In group D, significantly lower basal concentrations of N-acetylaspartate (p=0.02), choline (p=0.03), creatine (p=0.002) and inositol (p=0.007) were detected compared to C. After the induction of hyperinsulinemia, concentrations of choline, creatine, GABA, inositol, lactate, NAA and composite signal glutamate + glutamine (Glx) stayed stable. The detection of glucose signal is less realiable at 1.5 Tesla but we registered the alteration in glucose concentration (p=0.003) in the whole group. Originally sightly elevated glucose concentration in D decreased on the contrary to the increase of originally lower glucose level in C. In conclusions, brain metabolism was altered in D. Short term supraphysiological euglycemic hyperinsulinemia induced changes in the concentration of brain glucose in both C and D., S. Kratochvílová, A. Škoch, M. Dezortová, E. Švehlíková, M. Hill, J. Brunová, M. Hájek, T. Pelikánová., and Obsahuje bibliografii
Cíl: Práce shrnuje naše první zkušenosti se stanovením obsahu tuku a železa v játrech na 3T přístroji pomocí softwaru využívajícího současně techniku two-point Dixon, techniku multiechoDixon kombinovanou s T2* relaxometrií a single voxel 1H spektroskopii v kombinaci s T2 relaxometrií. Metodika: Do studie bylo zahrnuto 55 MR vyšetření jater provedených na 3T přístroji za použití softwarového balíku Liver-Lab (Siemens, Erlangen, Německo), který obsahuje sekvence a posprocessingové nástroje umožňující stanovit obsah tuku a železa pomocí výše uvedených technik. Jako referenční metody jsme použili 1H single voxel spektroskopii a sérovou hladinu feritinu. Výsledky: Technika two-point Dixon dosáhla při rozhodování o přítomnosti steatózy ve srovnání se spektroskopií senzitivity (SE) 72,4 % a specificity (SP) 80,7 %. Technika multiecho Dixon v oblasti zájmu, která se shodovala s oblastí zájmu pro spektroskopii, měla při rozhodování o přítomnosti steatózy SE 72,4 % a SP 92,3 %. Při kvantifikaci dosáhla velmi vysoké shody se spektroskopií r = 0,93. Při rozhodování o přítomnosti jaterní siderózy měla technika two-point Dixon SE 69,2 % a SP 60,0 %. T2* relaxometrie měla při rozhodování o přítomnosti siderózy SE 92,3 % a SP 100 %. Při kvantifikaci dosáhla vysoké shody se sérovými hladinami feritinu, r = 0,74. U T2 relaxometrie byla při rozhodování o přítomnosti siderózy SE 61,5 % a SP 80,0 %. Shoda se sérovými hladinami feritinu byla nízká, r = 0,28. Při srovnání T2 a T2* relaxometrie byla shoda obou metod nízká, r = 0,38. Závěr: Ve studii se ukazuje, že ze srovnávaných metod pro současné stanovení koncentrace tuku a železa v játrech je z praktického hlediska nevýhodnější technika multiecho Dixon spojená s T2* relaxometrií. Klíčová slova: magnetická rezonance, two-point Dixon, Multiecho Dixon, 1H MR spektroskopie, T2* relaxometrie, T2 relaxometrie, Aim: Our study deals with our first experience with quantification of liver fat and iron concentration at 3T MRI using two-point Dixon technique, multiecho Dixon technique combined with T2* relaxometry and single voxel 1H spectroscopy in combination with T2 relaxometry. Methods: 55 MR examinations were included into the study. The examinations were performed using a software package Liver-Lab (Siemens, Erlangen, Germany), which contains the sequence and posprocessing tools enabling evaluation using techniques that are mentioned above. As reference methods we used 1H single voxel spectroscopy and serum ferritin. Results: In decision on the presence of steatosis two-point Dixon reached sensitivity (SE) 72.4% and specificity (SP) 80.7% compared to MR spectroscopy. Multiecho Dixon with measurement in the regio of interest that coincide with the area of interest for spectroscopy, had in decision on the presence of steatosis SE 72.4% and 92.3% SP. In quantification it reached a very high agreement with spectroscopy, r = 0.93. When deciding on the presence of hepatic siderosis two-point Dixon compared to serum feritine level reached SE 69,2% and SP 60.0%. T2* relaxometry had in decision on the presence of siderosis SE 92.3% and SP 100%. In quantification it reached a high agreement with serum ferritin, r = 0.74. At T2 relaxometry was when deciding on the presence siderosis SE 61.5% and 80.0% SP. Agreement with serum ferritin was low, r = 0.28. When comparing T2 and T2* relaxometry the agreement of both methods was low, r = 0.38. Conclusion: Our study shows that multiecho Dixon technique combined with T2* relaxometry is from practical point of view the most suitable technique for simultaneous estimation of the liver steatosis and siderosis. Key words: magnetic resonance, two-point Dixon, multiechoDixon, 1H MR spectroscopy, T2* relaxometry, T2 relaxometry, Mírka H., Ferda J., Jindra P., Steinerová K., Hejda V., and Literatura
Indikace zobrazovacích metod prodělaly v posledních letech mimořádný vývoj. Spojené aplikace magnetické rezonance, jako jsou spektroskopie, difuzní zobrazení a farmakokinetická analýza pomohly zařadit do diagnostického algoritmu karcinomu prostaty efektivní komplexní vyšetřovací protokol pro nemocné se zvýšenými hladinami PSA. Pro případ nutností přesného posouzení lokálního šíření tumoru zůstávají nejefektivnější T2 vážené obrazy s vysokým prostorovým rozlišením. Zavedení cholinu značného fluorem 18 do klinické praxe umožnilo rutinní použití PET/CT nejen pro vlastní detekci nádoru, ale i pro hodnocení uzlinových a kostních metastáz. Při restagingu je odhalení příčiny biochemického relapsu onemocnění také možnou indikací 18F-FCH-PET/CT, které vykazuje vyšší úspěšnost než magnetická rezonance. Nádorem vyvolanou indukci osteoblastické aktivity u ve skeletu disseminovaného onemocnění je možné hodnotit pomocí 18F-NaF-PET/CT., The indications of the imaging methods underwent the exceptional evolution in last years. The united applications of the magnetic resonance imaging including the spectroscopy, diffusion imaging and pharmacokinetic evaluation helped to introduce the complex diagnostic algorithm to patients with pathologically elevated PSA levels. In cases of needed precise local staging, the most effective modality remains general T2 weighted imaging using high resolution data acquisition. The introduction of the choline labeled with fluorine 18 enables the routine clinical use of PET/CT not only in detection of the tumor, but also in detection of lymph node and skeleton dissemination. In cases of restaging of the disease including biochemically relapsing tumor, the 18F-FCH-PET/ CT reached the important improvement in comparison to magnetic resonance. The tumor-induced osteoblastic activity in skeletally disseminated prostatic cancer could be assessed using 18F-NaF-PET/CT., Jiří Ferda, Jan Kastner, Eva Ferdová, Hynek Mírka, Milan Hora, Ondřej Hes, Jindřich Fínek, Boris Kreuzberg, and Literatura 16