Autologous vein grafts used as aortocoronary bypasses are often prone to intimal hyperplasia, which results in stenosis and occlusion of the vein. The aim of this study was to prevent intimal hyperplasia using a newly developed perivascular system with sustained release of sirolimus. This system of controlled drug release consists of a polyester mesh coated with a copolymer of L-lactic acid and ε -caprolactone that releases sirolimus. The mesh is intended for wrapping around the vein graft during surgery. The mesh releasing sirolimus was implanted in periadventitial position onto arteria carotis communis of rabbits, and neointimal hyperplasia was then assessed. We found that implanted sirolimus-releasing meshes reduced intima thickness by 47±10 % compared to a vein graft after 3 weeks. The pure polyester mesh decreased vein intima thickness by 35±9 %. Thus, our periadventitial system for controlled release of sirolimus prevented the develo pment of intimal hyperplasia in autologous vein grafts in vivo in rabbits. A perivascularly applied mesh releasing sirolimus is a promising device for preventing stenosis of autologous vein grafts., I. Skalský ... [et al.]., and Obsahuje bibliografii a bibliografické odkazy
Cardiac resynchronization therapy is not commonly used in the early postoperative period in pati ents undergoing cardiac surgery who have left ventricular (LV) dysfunction and a history of heart failure. We performed a prospective randomized clinical trial to compare atrial synchronous right ventricular (DDD RV) and biventricular (DDD BIV) pacing within 72 hours after cardiac surgery in patients with an EF ≤ 35 %, a QRS interval longer than 120 msec and who had LV dyssynchrony detected by real-time three-dimensional echocardiography (RT3DE). Epicardial pacing was provided by a modified Medtronic INSYNC III pacemaker. An LV epicardial pacing lead was implanted on the latest activated segment of the LV based on RT3DE. The study included 18 patients with ischemic heart diseas e, with or without valvular heart disease (14 men, 4 women, average age 71 years). Patients undergoing DDD BIV pacing had a statistically significant greater CO and CI (CO 6.7±1.8 l/min, CI 3.4±0.7 l/min/m²) than patients undergoing DDD RV pacing (CO 5.5±1.4 l/min, CI 2.8±0.7 l/min/m²), p<0.001. DDD BIV paci ng in the early postoperative period after cardiac surgery corrects LV dyssynchrony and has better hemodynamic results than DDD RV pacing., F. Straka ... [et al.]., and Obsahuje bibliografii a bibliografické odkazy
Pulmonary hypertension (PH) unresponsive to pharmacological intervention is considered a contraindication for orthotopic heart transplantation (OHTX) due to risk of postoperative right-heart failure. In this prospective study, we describe our experience with a treatment strategy of improving severe PH in heart transplant candidates by means of ventricular assist device (VAD) implantation and subs equent OHTX. In 11 heart transplantation candidates with severe PH unresponsive to pharmacological intervention we implanted VAD with the aim of achieving PH to values acceptable for OHTX. In all patients we observed significant drop in pulmonary pr essures, PVR and TPG (p<0.001 for all) 3 months after VAD implantation to values sufficient to allow OHTX. Seven patients underwent transplantation (mean duration of support 216 days) while none of patients suffered right-side heart failure in postoperative period. Two patients died after transplantation and five patients are living in very good condition with a mean duration of 286 days after OHTX. In our opinion, severe PH is not a contraindication for orthotopic heart transplantation any more., J. Kettner ... [et al.]., and Obsahuje bibliografii a bibliografické odkazy