Cardiac resynchronization therapy is not commonly used in the early postoperative period in pati ents undergoing cardiac surgery who have left ventricular (LV) dysfunction and a history of heart failure. We performed a prospective randomized clinical trial to compare atrial synchronous right ventricular (DDD RV) and biventricular (DDD BIV) pacing within 72 hours after cardiac surgery in patients with an EF ≤ 35 %, a QRS interval longer than 120 msec and who had LV dyssynchrony detected by real-time three-dimensional echocardiography (RT3DE). Epicardial pacing was provided by a modified Medtronic INSYNC III pacemaker. An LV epicardial pacing lead was implanted on the latest activated segment of the LV based on RT3DE. The study included 18 patients with ischemic heart diseas e, with or without valvular heart disease (14 men, 4 women, average age 71 years). Patients undergoing DDD BIV pacing had a statistically significant greater CO and CI (CO 6.7±1.8 l/min, CI 3.4±0.7 l/min/m²) than patients undergoing DDD RV pacing (CO 5.5±1.4 l/min, CI 2.8±0.7 l/min/m²), p<0.001. DDD BIV paci ng in the early postoperative period after cardiac surgery corrects LV dyssynchrony and has better hemodynamic results than DDD RV pacing., F. Straka ... [et al.]., and Obsahuje bibliografii a bibliografické odkazy
Left ventricular assist devices (LVAD), currently used in treatment of terminal heart failure, are working on principle of rotary pump, which generates continuous blood flow. Non-pulsatile flow is supposed to expose endothelial cells to high stress and potential damage. Therefore, we investigated longitudinal changes in concentration of circulating endothelial microparticles (EMP) as a possible marker of endothelial damage before and after implantation of LVAD. Study population comprised 30 patients with end-stage heart failure indicated for implantation of the Heart Mate II LVAD. Concentrations of microparticles were measured as nanomoles per liter relative to phosphatidylserine before and 3 months after implantation. At 3 months after implantation we observed significant decrease in concentration of EMP [5.89 (95 % CI 4.31-8.03) vs. 3.69 (95 % CI 2.70-5.03), p=0.03] in the whole group; there was no difference observed between patients with ischemic etiology of heart failure (n=18) and with heart failure of non-ischemic etiology (n=12). In addition, heart failure etiology had no effect on the rate of EMP concentration decrease with time. These results indicate possibility that LVAD do not cause vascular damage 3 months after implantation. Whether these results suggest improvement of vascular wall function and of endothelium is to be proved in long-term studies., P. Ivak, J. Pitha, P. Wohlfahrt, I. Kralova Lesna, P. Stavek, Z. dorazilova, J. Stepankova, J. Maly, M. Pokorny, I. Netuka., and Obsahuje bibliografii
Pulmonary hypertension (PH) unresponsive to pharmacological intervention is considered a contraindication for orthotopic heart transplantation (OHTX) due to risk of postoperative right-heart failure. In this prospective study, we describe our experience with a treatment strategy of improving severe PH in heart transplant candidates by means of ventricular assist device (VAD) implantation and subs equent OHTX. In 11 heart transplantation candidates with severe PH unresponsive to pharmacological intervention we implanted VAD with the aim of achieving PH to values acceptable for OHTX. In all patients we observed significant drop in pulmonary pr essures, PVR and TPG (p<0.001 for all) 3 months after VAD implantation to values sufficient to allow OHTX. Seven patients underwent transplantation (mean duration of support 216 days) while none of patients suffered right-side heart failure in postoperative period. Two patients died after transplantation and five patients are living in very good condition with a mean duration of 286 days after OHTX. In our opinion, severe PH is not a contraindication for orthotopic heart transplantation any more., J. Kettner ... [et al.]., and Obsahuje bibliografii a bibliografické odkazy