In order to study a possible effect of mini-invasive heart intervention on a response of hypothalamo-pituitary-adrenal stress axis, we analyzed four stress markers (cortisol, cortisone, DHEA and DHEAS) in 25 sows using minimally invasive heart catheterisation as the stress factor. The marker levels were assessed in four periods of the experiment, (1) the baseline level on the day before intervention, (2) after the introduction of anesthesia, (3) after conducting tissue stimulation or ablation, and (4) after the end of the catheterisation. For statistical analyses we used the non-parametric Friedman test for four dependent samples (including all four stages of the operation) or three dependent samples (influence of operation only, baseline level was excluded). Statistically significant differences in both Friedman tests were found for cortisol and for cortisone. Significant differences for DHEA as well as for DHEAS were found for all tested stages but not for the effect of operation itself. We have concluded that cortisol levels are blunted by the influence of anesthesia after its administration, and therefore decrease back to the baseline at the end of the operation. The other markers (cortisone, DHEA and DHEAS) acted as balanced systems against the injurious stress effect., H. Skarlandtová, M. Bičíková, P. Neužil, M. Mlček, V. Hrachovina, T. Svoboda, E. Medová, J. Kudlička, A. Dohnalová, Š. Havránek, H. Kazihnítková, L. Máčová, E. Vařejková, O. Kittnar., and Obsahuje bibliografii
An increased risk of myocardial ischemic changes was demonstrated in patients suffering from panic disorder (PD). Using classical ECG methods, this risk cannot be evaluated in most patients. We measured the vectocardiogram (VCG) using Frank orthogonal leads and body surface maps (BSM) including 12-lead ECG. In our study of 11 PD patients (2 men, 9 women), without any seizures and pharmacological treatment and without cardiovascular symptoms, we found marked sinus tachycardia (heart rate 90.1±12.2 min-1) and a shorter R-R interval (678±93.6 ms) than in 27 controls (heart rate 73.6±7.7min-1, R-R 822.7±86.4 ms) (5 men, 22 women) (p<0.001). The VCG measured spatial QRS-STT angle was more opened (70.3±24.5°) than in the control group (49.5±19.5°) (p<0.05). The maximum (extremum) in depolarization (DIAM max 30, 40) and repolarization (RIAM max 35) of body surface isoarea and isointegral (RIIM max) maps was less positive (p<0.001) and the minimum (DIAM min 40) was less negative than in the controls (p<0.05) even in the period free of a panic attack. Our results showed the changes in the heart electric field parameters occurred in PD patients when compared to the control group., K. Pišvejcová, I. Paclt, J. Slavíček, O. Kittnar, A. Dohnalová, E. Kitzlerová., and Obsahuje bibliografii
Tricyclic antidepressant drugs dosulepine (TCA), serotonin selective reuptake inhibitor (SSRI) and prophylactic agent with antidepressant effect lithium carbonicum (Li) have different cardiovascular side-effects. We compared them in the prophylactic therapy of periodic affective disorder in remission with TCA, SSRI and Li. Our previous papers confirmed the most prominent effects of heart electric field parameters in TCA patients (Slavíček et al. 1998). In the present work we studied for the first time the dose-dependent changes of ECG, body surface potential maps (BSPM - parameter DIAM 30, 40) in 43 TCA dosulepine, 40 SSRI citalopram and 30 Li outpatients (Hamilton scale: HAMD£10; age 40±5 years; treated for depressive disorders or bipolar disorders). The daily doses of dosulepine were 50-250 mg, citalopram 20-80 mg, Li plasma levels 0.66±0.08 meq/l. The electrocardiogram (ECG), vectorcardiogram (VCG), and BSPM were measured and calculated by the Cardiag 112.1 diagnostic system. The results have shown a relation between the dose of dosulepine and extremum (maximum and minimum) of depolarization isoarea map in dosulepine, but not in citalopram patients. The repolarization BSPM changes were most pronounced in SSRI patients. Lithium in long-term prophylaxy (1-22 years) caused only minimal ECG BSPM changes. The present results correspond with our previous observations., I. Paclt, J. Slavíček, A. Dohnalová, E. Kitzlerová, K. Pišvejcová., and Obsahuje bibliografii
Glucocorticoids (GCs) are steroid hormones produced by the adrenal cortex in reaction to stress stimuli. GCs production is not stable over a 24-hour period; the plasma concentration peaks in the morning (approximately upon awakening) and then the plasma levels decrease, reaching the nadir in the evening. In our experiments, the levels of cortisol, cortisone, DHEA and DHEAS were tested in young female pigs (n=23) during heart catheterization at two different day times (in the morning and in the afternoon). The non-parametric Mann-Whitney test for statistical analysis was used. We found only minimal statistical differences in studied markers between the morning and afternoon group (p>0.05). The absence of circadian variation in GCs levels could originate either at an early age of our experimental pigs, or in stressful conditions on the experiment day, or most likely the day before (e.g. social isolation, fasting, transport, and catheterization), respectively. We can conclude there is no difference in the stress load between morning and afternoon experiments, and therefore we can assume the stress load is not a limiting factor for the timing when catheterization should be preferably performed., H. Skarlandtová ... [et al.]., and Obsahuje seznam literatury
Antidepressants, particularly tricyclic (TCA) antidepressants, may have cardiotoxic effects, such as cardiac arrhythmias, especially in patients with cardiovascular diseases. For most of TCA, no exact correlation between dosage, plasma levels and changes of ECG parameters of standard ECG has been found. So far, no relationship between dosulepine plasma levels and heart electric field parameters has been studied. We selected 18 female outpatient subjects diagnosed with recurrent depressive disorders, currently in the remission phase (HAMD < 10), without any cardiovascular disease. Patients were treated with daily dosulepine doses of 25-125 mg for 4-8 weeks. 30 heart electric field parameters were analyzed by Cardiag 128.1 diagnostic system as part of BSPM (Body Surface Potential Mapping). Acquired data were correlated with dosulepine plasma levels by means of Spearmanís rank order correlation test. Four ECG parameters showed a significant correlation with dosulepine plasma levels: QRS axis deviation in frontal plane (p=0.01), DIAM 40 max (p < 0.05), QRS-STT angle in transversal and left sagittal plane (p < 0.05). The demonstrated changes confirmed dosulepine influence on the early myocardium depolarization phase and the correlation of this effect with dosulepine dose (its plasma concentration). The higher the dosulepine level, the more marked are the changes of the QRS-STT angle in transversal and sagittal planes and the changes in the QRS axis deviation in frontal plane. Repeatedly recorded changes in the heart electric field were dosulepine-specific and dependent on its plasma levels., E. Kitzlerová, I. Paclt, J. Slavíček, K. Pišvejcová, M. Anders, A. Dohnalová, M. Balíková., and Obsahuje bibliografii
Negative expiratory pressure (NEP) applied at the mouth during tidal expiration provides a non-invasive method for detecting expiratory flow limitation. Forty-two children were studied, i.e. 25 children with different respiratory symptoms (R) and 17 without any respiratory symptoms (NR). Children were examined without any sedation. A preset NEP of -5 cm H 2 O was applied; its duration did not exceed duration of tidal expiration. A significance of FL was judged by determining of a flow-limited range (in % of tidal volume). FL was found in 48 % children of R group. No patient of the NR group elicited FL (P<0.001 R vs. NR). The frequency of upper airway collapses was higher in R group (12 children) than in NR gr oup (5 children). In conclusion, a high frequency of tidal FL in the R group was found, while it was not present in NR group. A relatively high frequency of expiratory upper airway collapses was found in both groups, but it did not differ significantly. NEP method represents a reasonable approach for tidal flow limitation testing in non-sedated preschool children., A. Jiřičková, J. Šulc, P. Pohunek, O. Kittnar, A. Dohnalová, J Kofránek., and Obsahuje bibliografii
Gestational diabetes mellitus (GDM) represents additional risks to both mother and infant. Moreover it increases a woman's risk of cardiovascular disease in the postpartum. The aim of our study was therefore to detect changes of both the QT dispersion and the electrical heart field that could be typical for GDM. Body surface potential maps were obtained using the Cardiac 112.2 device from 26 young women with GDM and 54 young healthy pregnant women in the 36th week of pregnancy. The same recordings were obtained from 18 healthy women in the same age (19-36 years). The average QT dispersion (±SD) in women suffering from GDM was significantly higher (107±25 ms) both than in those with physiological pregnancy (73±18 ms) and than in the normal subjects (34±12 ms) (P<0.001). Moreover we have found in GDM patients shorter QRS complex 82.0±6.8 ms vs. 89.5±8.2 ms in healthy pregnant women and 90.8±7.9 ms in the control group (p=0.011), more horizontal electrical heart axis [16.4±20.1° vs. 42.4±28.7° and 74.6±39.2° respectively (P<0.05)] and lower some depolarization and repolarization amplitudes on isopotential and isointegral maps. According to these results we suppose that described electrocardiographic changes reflect a deterioration of the complete process of ventricular depolarization and repolarization in GDM., E. Medová, ... [et al.]., and Obsahuje seznam literatury
The aim of the study was to detect changes of both the QT dispersion and T-loop morphology resulting from the changed spatial position of the heart during pregnancy. Electrocardiographic and vectorcardiographic recordings were obtained from 37 healthy women 19-36 years old in the 36th to 40th week of physiological pregnancy and 2 to 6 days after delivery. The same recordings were obtained from 18 healthy women of the same age. The average QT dispersion (±S.D.) in normal subjects was significantly lower (34±12 ms) than in those in late pregnancy (73±18 ms) (P<0.001). The average amplitude of T-loop (Ta) in women in late pregnancy was significantly (P<0.001) smaller (532±98 mV) and the width of T-loop (Tw) was wider (21.24±11.48 deg) than in the control group (793±114 mV and 7.17±3.02 deg, respectively). The partial post-partum restoration of all parameters was not significant. In all groups, the QT dispersion was significantly correlated with Tw but not with Ta. According to these results we can conclude that the QT dispersion is an indirect reflection of the complete process of ventricular repolarization, reflected in the morphology of the T-loop., M. Lechmanová, O. Kittnar, M. Mlček, J. Slavíček, A. Dohnalová, Š. Havránek, J. Kolařík, A. Pařízek., and Obsahuje bibliografii