Gestational diabetes mellitus (GDM) represents additional risks to both mother and infant. Moreover it increases a woman's risk of cardiovascular disease in the postpartum. The aim of our study was therefore to detect changes of both the QT dispersion and the electrical heart field that could be typical for GDM. Body surface potential maps were obtained using the Cardiac 112.2 device from 26 young women with GDM and 54 young healthy pregnant women in the 36th week of pregnancy. The same recordings were obtained from 18 healthy women in the same age (19-36 years). The average QT dispersion (±SD) in women suffering from GDM was significantly higher (107±25 ms) both than in those with physiological pregnancy (73±18 ms) and than in the normal subjects (34±12 ms) (P<0.001). Moreover we have found in GDM patients shorter QRS complex 82.0±6.8 ms vs. 89.5±8.2 ms in healthy pregnant women and 90.8±7.9 ms in the control group (p=0.011), more horizontal electrical heart axis [16.4±20.1° vs. 42.4±28.7° and 74.6±39.2° respectively (P<0.05)] and lower some depolarization and repolarization amplitudes on isopotential and isointegral maps. According to these results we suppose that described electrocardiographic changes reflect a deterioration of the complete process of ventricular depolarization and repolarization in GDM., E. Medová, ... [et al.]., and Obsahuje seznam literatury
The aim of the study was to detect changes of both the QT dispersion and T-loop morphology resulting from the changed spatial position of the heart during pregnancy. Electrocardiographic and vectorcardiographic recordings were obtained from 37 healthy women 19-36 years old in the 36th to 40th week of physiological pregnancy and 2 to 6 days after delivery. The same recordings were obtained from 18 healthy women of the same age. The average QT dispersion (±S.D.) in normal subjects was significantly lower (34±12 ms) than in those in late pregnancy (73±18 ms) (P<0.001). The average amplitude of T-loop (Ta) in women in late pregnancy was significantly (P<0.001) smaller (532±98 mV) and the width of T-loop (Tw) was wider (21.24±11.48 deg) than in the control group (793±114 mV and 7.17±3.02 deg, respectively). The partial post-partum restoration of all parameters was not significant. In all groups, the QT dispersion was significantly correlated with Tw but not with Ta. According to these results we can conclude that the QT dispersion is an indirect reflection of the complete process of ventricular repolarization, reflected in the morphology of the T-loop., M. Lechmanová, O. Kittnar, M. Mlček, J. Slavíček, A. Dohnalová, Š. Havránek, J. Kolařík, A. Pařízek., and Obsahuje bibliografii
Sudden death is a possible occurrence for newborns younger than 1 year with severe aortic coarctation (CoA) before surgical correction. In our previous study, we showed a significant increase of QTc-D and JTc-D in newborns with isolated severe aortic coarctation, electrocardiog raphic parameters that clinical and experimental studies have suggested could reflect the physiological variability of regional and ventricular repolarization and could provide a substrate for life-threatening ventricular arrhythmias. The aim of the current study was to evaluate the effect of surgical repair of CoA on QTc-d, JTc-d in severe aortic coarctation newborns with no associated congenital cardiac malformations. The study included 30 newborns (18M; 70±12 h old) affected by severe congenit al aortic coarct ation, without associated cardiac malformation s. All newborns underwent to classic extended end-to-end repair. Echocardiographic and electrocardiographic measurements were performed in each patient 24 h before and 24 h afte r the interventional procedure and at the end of the follow-up period, 1 month after the surgical correction. All patients at baseline, 24 h and one month after CoA surgical repair did not significantly differ in terms of heart rate, weight, height, and echocardiographic parameters. There were no statistically significant differences in QTc-D (111.7±47.4 vs 111.9±63.8 ms vs 108.5±55.4 ms; P =0.4) and JTc-D (98.1±41.3 vs 111.4±47.5 vs 105.1±33.4 ms; P =0.3) before, 24 h and 1 month after CoA surgical correction. In conclusions, our study did not show a statistically signif icant decrease in QTc-D and JTc- D, suggesting the hypothesis that the acute left ventricular afterload reduction, related to successful CoA surgical correction, may not reduce the ventricular electrical instability in the short- term follow-up., G. Nigro ... [et al.]., and Obsahuje bibliografii a bibliografické odkazy