Left ventricular assist devices (LVAD), currently used in treatment of terminal heart failure, are working on principle of rotary pump, which generates continuous blood flow. Non-pulsatile flow is supposed to expose endothelial cells to high stress and potential damage. Therefore, we investigated longitudinal changes in concentration of circulating endothelial microparticles (EMP) as a possible marker of endothelial damage before and after implantation of LVAD. Study population comprised 30 patients with end-stage heart failure indicated for implantation of the Heart Mate II LVAD. Concentrations of microparticles were measured as nanomoles per liter relative to phosphatidylserine before and 3 months after implantation. At 3 months after implantation we observed significant decrease in concentration of EMP [5.89 (95 % CI 4.31-8.03) vs. 3.69 (95 % CI 2.70-5.03), p=0.03] in the whole group; there was no difference observed between patients with ischemic etiology of heart failure (n=18) and with heart failure of non-ischemic etiology (n=12). In addition, heart failure etiology had no effect on the rate of EMP concentration decrease with time. These results indicate possibility that LVAD do not cause vascular damage 3 months after implantation. Whether these results suggest improvement of vascular wall function and of endothelium is to be proved in long-term studies., P. Ivak, J. Pitha, P. Wohlfahrt, I. Kralova Lesna, P. Stavek, Z. dorazilova, J. Stepankova, J. Maly, M. Pokorny, I. Netuka., and Obsahuje bibliografii
Many functions of the cardiovascular apparatus are affected by gender. The aim of our study was find out whether markers of cell death present in the donor myocardium differ in male and female hearts. The study involved 81 patients undergoing heart transplantation from September 2010 to January 2013. Patients were divided into two groups: male allograft (n=49), and female allograft (n=32). Two types of myocardial cell death were analyzed. High-sensitive cardiac troponin T as a necrosis marker and protein bcl-2, caspase 3 and TUNEL as apoptosis markers were measured. We observed a significantly higher level of high-sensitive cardiac troponin T after correcting for predicted ventricular mass in female donors before transplantation as well as in the female allograft group after transplantation throughout the monitored period (P=0.011). There were no differences in apoptosis markers (bcl-2, caspase 3, TUNEL) between male and female hearts before transplantation. Both genders showed a significant increase of TUNEL-positive myocytes one week after transplantation without differences between the groups. Moreover, there were no differences in caspase 3 and bcl-2
expression between the two groups. Our results demonstrated the presence of necrotic and apoptotic cell death in human heart allografts. High-sensitive cardiac troponin T adjusted for predicted ventricular mass as a marker of myocardial necrosis was higher in female donors, and this gender difference was even more pronounced after transplantation.