The aim of our study was to evaluate the adequacy of a new mapping device for obtaining a reliable set of normal maps characteristic for this approach. We studied body surface isochrone maps of peak R in four healthy adolescent girls using the mapping system CARDIAG 128.1 with 80 unipolar leads placed in a regular grid. The constructed maps were compared with published data using 10 criteria. None of the maps obtained could be regarded as normal. After evaluating the reasons for the "abnormality", we assume that they could be caused mostly by the processing of signals. This fact can be eliminated by improving the existing software.
V článku je představen systém pro mnohokanálové měření a povrchové mapování EKG potenciálů a možnosti jeho využití při diagnostice ischemické choroby srdeční. Systém může používat až 128 aktivních EKG elektrod. Povrchové potenciály jsou měřeny vzhledem k přemístitelné vztažné elektrodě, což spolu s aktivní kompenzací synfázního rušení z pacienta zajišťuje optimální kvalitu měřených signálů. Mikroprocesorem řízená, z baterie napájená snímací jednotka je připojena k ethernetovému portu osobního počítače pomocí optického kabelu. Software pro měření a zpracování signálů je navržen pro platformu Windows. Umožňuje například lokalizaci a odhad velikosti poškození při infarktu myokardu pomocí odchylkových integrálních map, nebo neinvazivní identifikaci ložiskové ischemie pomocí dipólového modelu elektrického generátoru srdce, určeného na základě změn v integrálních EKG mapách na povrchu pacientova hrudníku jakožto nehomogenního objemového vodiče., P. Kneppo, V. Rosík, M. Tyšler, S. Karas, K. Hána, P. Smrčka, E. Hebláková, J. Mužík, S. Filipová., and Obsahuje seznam literatury
In the present study we investigated the contribution of ventricular repolarization time (RT) dispersion (the maximal difference in RT) and RT gradients (the differences in RT in apicobasal, anteroposterior and interventricular directions) to T-wave flattening in a setting of experimental diabetes mellitus. In 9 healthy and 11 diabetic (alloxan model) open-chest rabbits, we measured RT in ventricular epicardial electrograms. To specify the contributions of apicobasal, interventricular and anteroposterior RT gradients and RT dispersion to the body surface potentials we determined T-wave voltage differences between modified upper- and lower-chest precordial leads (T-wave amplitude dispersions, TWAD). Expression of RT gradients and RT dispersion in the correspondent TWAD parameters was studied by computer simulations. Diabetic rabbits demonstrated flattened T-waves in precordial leads associated with increased anteroposterior and decreased apicobasal RT gradients (P<0.05) due to RT prolongation at the apex. For diabetics, simulations predicted the preserved T-vector length and altered sagittal and longitudinal TWAD proven by experimental measurements. T-wave flattening in the diabetic rabbits was not due to changes in RT dispersion, but reflected the redistributed ventricular repolarization pattern with prolonged apical repolarization resulting in increased anteroposterior and decreased apicobasal RT gradients.