The article presents an experimental method for the three-dimensional (3D) imaging of ferroelectric domain structures using the method of digital holographic tomography. The implementation of this method uses curvilinear filtered back-projection. Our experimental method is tested by the visualization of the domain structures in the periodically poled lithium niobate single crystal. The developed method enables fast and accurate 3D observation of structures of ferroelectric domains in the whole volume of ferroelectric single crystals. and Článek prezentuje experimentální metodu pro trojrozměrné (3D) zobrazování feroelektrických doménových struktur za použití metody digitální holografické tomografie. Implementace této metody využívá křivočarou filtrovanou zpětnou projekci. Naše experimentální metoda je testována na zobrazování doménových struktur v periodicky polarizovaném monokrystalu niobátu lithia. Vyvinutá metoda umožňuje rychlé a přesné 3D pozorování struktur feroelektrických domén v celém objemu feroelektrických monokrystalů v milimetrovém měřítku.
Single-miracidium infections of Lymnaea cubensis (Pfeiffer) from Guadeloupe with the giant liver fluke Fascioloides magna (Bassi, 1875) (Digenea) were carried out during five successive snail generations to determine if this lymnaeid might sustain complete larval development of the parasite. Controls were constituted by a French population of Galba truncatula (Müller) (a single generation) infected according to the same protocol. It was recorded that prevalence and intensity of F. magna infection in L. cubensis progressively increased from F1 to F5 generations. Cercarial shedding of F. magna was noted only within F5 generation of L. cubensis. However, most measured parameters of infection in this species were significantly lower than those noted for G. truncatula and most L. cubensis died after a single shedding wave. Despite this, L. cubensis can be added to the list of potential intermediate hosts of F. magna.
The paper is focused on refractive index measurement of liquids by surface plasmon resonance (SPR). There are presented two variants of experimental setup. Functionality of experimental arrangement was analyzed by two steps, the first approach was realized by variously concentrated NaCl water solutions and the second one has been done by the change of water temperature. and Článek je věnován měření změn indexu lomu kapalin využitím metody rezonance povrchových plasmonů (Surface Plasmon Resonance - SPR), realizovanému na našem pracovišti. Jsou zde představeny dvě varianty experimentálního uspořádání. Funkčnost obou zařízení a relevance měřených hodnot byla nejprve ověřena souborem měření na různě koncentrovaných roztocích NaCl ve vodě. Poté byla metoda SPR aplikována na studium změn reflektivity při použití vody proměnné teploty.