The presented work follows the first part [1], which is focused on the analysis of bone tissue in terms of dependence of bone tissue 'quality' and its subsequent behaviour based on the stress around the disk implant when biting.
This second part is focused on the stress-strain analysis (and tolerability) of disk implants as loaded during the masticating process.
The study includes two types of disk implants (single-disk and double-disk), three types of anchorage, four degrees (stages) of osseointegration in three quality degrees of the cancellous bone. The study, as expected, has shown that the problematic area of he implants is a transition between the implant body and the disk component, where the equivalent stress in the analyzed implants reaches 700 MPa. and Obsahuje seznam literatury