The presented work is focused on the biomechanical study of the dental disk implant. The first part of the study deals with the strain analysis of the affected bone tissue and the dental implant loaded in the coronoapical direction by force 190 N. The study includes three types of implant anchorge, four degrees (stages) of osseointegration and nine degrees describing the quality of the cancellous bone. Two types of the disk implant were researched: single-disk and double-disk implant. Biomechanical study of the implant was focused on a stress-strain analysis of the affected bone rissue. The highest influence on the stresses in the bone tissue was primarily an implant anchorage. By the application of correlation relationships between Young modulus and the apparent density of the bone tissue - which is measurable in patients - we achieved the variable presented in this study. and Obsahuje seznam literatury
The presented work follows the first part [1], which is focused on the analysis of bone tissue in terms of dependence of bone tissue 'quality' and its subsequent behaviour based on the stress around the disk implant when biting.
This second part is focused on the stress-strain analysis (and tolerability) of disk implants as loaded during the masticating process.
The study includes two types of disk implants (single-disk and double-disk), three types of anchorage, four degrees (stages) of osseointegration in three quality degrees of the cancellous bone. The study, as expected, has shown that the problematic area of he implants is a transition between the implant body and the disk component, where the equivalent stress in the analyzed implants reaches 700 MPa. and Obsahuje seznam literatury