Patients treated for knee disorders were included in this study. They were examined clinically (Lequesne and Tegner scores) and by standard X-ray investigation. Patients underwent a surgical procedure, either arthroscopy or knee replacement. At the initial phase of surgery, a sample of cartilage was taken for laboratory examination. Progression of the disorder and the clinical examination was correlated with the actual state of the cartilage using a novel fluorescence approach. The intrinsic fluorescence of cartilages was shown as a suitable and sensitive method for detection of the actual state of cartilages because the correlation with X-ray examination and clinical status was found. Intrinsic fluorescence properties of cartilages from patients with chondropathy and osteoarthritis were described and found to be age-dependent. We also observed a higher concentration of advanced glycation end products due to inflammatory and/or degenerative processes in the cartilage. In addition, acute pathological changes due to diseases such as meniscal lesions or anterior cruciate ligament rupture caused a significant increase of formation of advanced glycation end products even in the group of young patients. In fact, such an observation could be crucial and important for the detection of knee conditions suspected of early meniscal and/or ACL lesions especially among young patients., M. Handl, E. Filová, M. Kubala, Z. Lánský, L. Koláčná, J. Vorlíček, T. Trč, M. Pach, E. Amler., and Obsahuje bibliografii a bibliografické odkazy
Myofibril-bound creatine kinase EC 2.7.3.2 (CK), a key enzyme of muscle energy metabolism, has been selected for studies of conformational changes that underlie the cellular control of enzyme activity. For fluorescence spectroscopy measurements, the CK molecule was double-labeled with IAF (5-iodoacetamidofluorescein) and ErITC (erythrosin 5'-isothiocyanate). Measurement of fluorescence resonance energy transfer (FRET) from fluorescein to erythrosin was used to obtain information about the donor-acceptor pair distance. Frequency-domain lifetime measurements evaluate the donor-acceptor distance in the native CK molecule as 7.8 nm. The Förster radius equals 5.3 nm with the resolution range from 0.2 to 1.0 nm. Erythrosin-fluorescein labeling (EFL) was tested for artificial conformational changes of the CK molecule with high-salt concentration treatment. The transition distance, defined by His-97 and Cys-283 and derived from a 3D model equals 0.766 nm for the open (inactive) form and 0.277 nm for the closed (reactive) form of the CK molecule. In this way, the resolution range of the used spectroscopy method is significant, concerning the difference of 0.489 nm. Nevertheless, the CK enzyme activity, assessed by the hexokinase-coupled assay, was diminished down to 1 % of the activity of the native enzyme. EFL is suitable for description of conformational behavior implied from the regulation of creatine kinase. However, the observed inhibition restricts EFL to studies of conformational changes during natural catalytic activity., M. Gregor, M. Kubala, E. Amler, J. Mejsnar., and Obsahuje bibliografii