Přehledové sdělení se věnuje diagnostickému zobrazení akutních aortálních syndromů s důrazem na multidetektorovou výpočetní tomografii a na její význam pro volbu léčby. Diskutovány jsou jednak techniky CT zobrazení včetně CT s EKG synchronizací a dále diagnostické nálezy u disekce aorty, intramurálního hematomu a penetrujícího vředu aorty. Literární data jsou konfrontována s vlastními zkušenostmi terciárního centra v populaci městského typu., Review payes attention to the importace of the diagnostic imaging in acute aortic syndromes concerning to the multidetector-row computed tomography and its impact on treatment decisions. The several CT techniques including CT with ECG synchronized acquisitions are discussed as well as the diagnostic findings of aortic dissection, intramural hematoma and penetrating aortic ulcer. Bibliographic data are faced with the own experience of the tertiary centre with urban population., Jiří Ferda, Petr Duras, Jan Baxa, František Šlauf, and Literatura
Cíl: Významem naší prospektivní studie je možnost významné redukce celkového objemu kontrastní látky při CTA DK díky optimalizaci akvizičního času na základě individuálních cirkulačních parametrů. Metoda: Celkem u 68 osob s ischemickou chorobou dolních končetin bylo prospektivně provedeno CT angiografické vyšetření břišní aorty a dolních končetin (CTA DK) s použitím kontrastní látky o objemu 40 ml (31 osob) a 50 ml (37 osob) a vysokou rychlostí aplikace (6 ml/s). Akviziční čas byl individuálně vypočten na základě aorto-popliteálního (Ao-P) tranzitního času získaného stanovením denzitní bolusové křivky na dvou úrovních (aorta/popliteální tepna) po jednorázovém podání 10 ml kontrastní látky (tzv. dvojitý testovací bolus). Kvalita vyšetření vyšetření byla hodnocena subjektivním (skóre 1-3) a objektivním měřením denzity v pěti úrovních. Vyšetření byla označena jako nediagnostická, pokud byla alespoň jedna oblast při subjektivním hodnocení ohodnocena skórem 3. Ve statistickém hodnocení byla porovnána dosažená kvalita s hodnotami akvizičního času a zpoždění. Výsledky: Prokázali jsme statisticky významnou korelaci akvizičního času (21-43) a subjektivního (p = 0,0015) a objektivního (p = 0,0117) hodnocení kvality. Také v případě Ao-P tranzitního času byla prokázána statistická korelace s hodnocením kvality (0,0013, resp. 0,0191). Signifikantně vyšší akviziční čas byl použit u vyšetření s celkově subjektivně nediagnostickou kvalitou (p = 0, 073) a ve všech případech byl vyšší než 31 s. Naopak všechna vyšetření s akvizičními časy pod 30 s byla plně diagnostická. Při podání 50 ml kontrastní látky bylo dosaženo významně vyšší denzity v jednotlivých sledovaných úrovních (p = 0,076), hodnoty akvizičního času a Ao-P tranzitního času se významně mezi skupinami s různým množstvím kontrastní látky nelišily. Závěr: Naše práce prokázala možnost významné redukce objemu kontrastní látky při CTA DK za pomoci optimalizace akvizičního času na základě Ao-P tranzitního času, který byl získán po jednorázové aplikaci 10 ml kontrastní látky (dvojitý test bolus). Byla prokázána statisticky významná korelace akvizičního času a Ao-P tranzitního času na kvalitě provedených vyšetření., Aim: The goal of the prospective study is to determine feasibility of peripheral CT angiography (CTA) with adaptive scan time using low volume of contrast agent. Methods: We performed CTA in extent of abdominal aorta and lower limbs on dual-source CT in two groups of patients with different volumes of contrast agent (400 mgl/l). Volumes of 40ml (31 patients) and 50 ml (21 patients) with 6ml/s injection were used for examinations. Individual scan time was calculated from peak transit time established from double test bolus (single administration of 10 ml) measurements (proximal abdominal aorta and popliteal arteries). We analyzed subjective quality of CTA (1-3) and objective quality (intraluminal density and CNR) in 5 different levels. Examinations with subjective quality 3 (non-diagnostic) in one level were considered as overall non-diagnostic. Results: We found significant correlation between scan time (21-43 s) and subjective (p = 0.0015) and objective quality (p = 0.0117) in both groups. Significantly higher (p = 0.029) scan time was used in examinations with overall non-diagnostic quality (6 in 40 ml group and 3 in 50 ml group). The scan times in non-diagnostic examinations were completely over 31s (31.6-42.4) and all examinations with scan time below 30 s were with excellent quality. Significantly better objective quality was reached in 50 ml group (p = 0.076). Time parameters were not significantly different in both groups. Conclusion: Our results have proved feasibility of peripheral CTA with adaptive scan time and low volume of contrast agent. There is significant correlation of used scan time and AoP peak transit time with quality with probability of determination of suitable group of patients., Jan Baxa, Jiří Ferda, Tomáš Vendiš, Jiří Moláček, Vladislav Třeška, and Literatura
Cíl. Práce je zaměřena na možnosti provedení CT angiografie břišní aorty a dolních končetin na nové generaci dvouzdrojového CT přístroje využívající skenování s vysokým pitch faktorem a ohledem na redukci radiační zátěže a množství podávané kontrastní látky. Metoda. V rámci prospektivní studie bylo vyšetřeno 29 osob s klinickými známkami či již známým postižením tepen dolních končetin. Vyšetření byla provedena na přístroji Somatom Definition FLASH (Siemens, Německo), použita kolimace 128 x 0,6 mm, rychlá rotace rentgenky (0,28 s/otáčku) a vyšším fázovým posunem (pitch faktor 1,55). Kontrastní látka v množství 60-70 ml byla aplikována rychlostí 5 ml/s, načasování akvizice bylo provedeno na základě monitorace testovacího bolusu (10 ml) v popliteálních tepnách. Hodnocení kvality zobrazení bylo provedeno na základě vizuálního posouzení a stanovení denzity v jednotlivých částech tepenného systému. Výsledky. Ve všech případech bylo dosaženo vysoké kvality zobrazení aorty, pánevních, femorálních i popliteálních tepen na základě vizuálního hodnocení i stanovení denzity (aorta - 456,3 HU, třísla - 507,3 HU, podkolenní - 554,3). V případě distální části bérců a nohy došlo u tří osob k suboptimální náplni vlivem rychlejší akvizice vůči postupu bolusu kontrastní látky. Pouze v jednom případě byla distální oblast bérců nehodnotitelná. Průměrná úroveň denzity v úrovni kotníků byla 367,7 HU. Průměrná radiační dávka byla nízká -CTDIvol 2,40, efektivní dávka 1,79 mSv. Závěr. První výsledky naší prospektivní studie prokázaly možnost provedení CT angiografie dolních končetiny pomocí "high-pitch" módu. Přes velmi nízkou hodnotu radiační dávky i aplikovaného množství kontrastní látky bylo dosaženo vysoké diagnostické kvality v oblasti aorty, pánve stehen a proximálních částí bérců. Tento způsob vyšetření je zvlášť vhodný pro osoby s vysokým rizikem kontrastní nefropatie, eventuálně pro mladé osoby v produktivním věku., Aim. Our work was focused on the feasibility of CT angiography of abdominal aorta and lower limbs using new generation of dual-source CT with a high pitch factor, concerning on the reduction of radiation exposure and the amount of administered contrast agent. Methods. In the prospective study were examined 29 patients with clinical signs, or known disability of lower limbs arteries. The examinations were performed on the Somatom Definition Flash (Siemens, Germany) using collimation 128 x 0.6 mm, high tube rotation speed (0.28 s/rotation) and a higher pitch factor of 1.55).Amount of contrast agent (60 to 70 ml) was applied at 5 ml/s, the timing of acquisition was based on results of the test bolus monitoring (10 ml) in the popliteal arteries. Evaluation of image quality was based on visual assessment and determination of density in different parts of the arterial system. Results. In all cases were achieved a high display quality of the aorta, pelvic, femoral and popliteal arteries by visual assessment and also determination of luminal density (aorta - 456.3 HU, groin - 507.3 HU, knee - 554.3). In the region of the distal leg and ankle occurred in 3 people in suboptimal quality due to overrun of bolus. Only in one case, the distal region leg was uninterpretable. The average level density at ankle level was 367.7 HU. The average radiation exposure was low - CTDIvol 2.40,1.79 mSv effective dose. Conclusion. The preliminary results of our prospective study showed the possibility of performing CT angiography of the lower limbs in "high-pitch" mode. Despite the very low radiation dose and the amount of applied contrast agent was achieved a high diagnostic quality of the aorta, pelvic, femoral, popliteal and proximal crural arteries. This test method should be especially recommended for people at high risk of contrast nephropathy and for young people., Jan Baxa, Jiří Ferda, Petr Duras, Jiří Moláček, Petr Havránek, Hynek Mírka, and Literatura 18
Cíl. Posoudit vliv iterativní rekonstrukce dat na efektivní dávky vyšetření CT s duální energií záření (DECT). Metoda. Byla zhodnocena efektivní dávka u celkem jedenácti skupin po 40 vyšetřeních provedených na dvouzdrojovém přístroji první a druhé generace za použití režimu jednozdrojového jednoenergetického a DECT s použitím iterativní rekonstrukce technikou sinogram affirmed iterative reconstruction (SAFIRE) v oblasti hrudníku a břicha včetně protokolů využívajících dvoufázové akvizice dat v režimu DECT. Výsledky. Bylo prokázáno pomocí t-testu pro nezávislé výběry, že mezi vyšetřeními na přístroji druhé generace dvouzdrojového CT s použitím iterativního algoritmu SAFIRE není statisticky významný rozdíl v dávce mezi režimem jednozdrojovým jedno-energetickým režimem DECT (p = 0,0299; 0,9337; 0, 8207), naopak významný rozdíl je mezi protokoly DECT bez iterativní rekonstrukce a s ní (p < 0,0001 u všech porovnání). Závěr. Iterativní rekonstrukce umožňuje významně snížit efektivní dávku i protokolech DECT a zachovat dávkovou neutralitu ve srovnání s vyšetřeními na jednozdrojových systémech., Aim. To evaluate the influence of the iterative reconstruction on the effective dose obtained from dual-energy CT (DECT). Method. The effective dose was calculated within the 11 groups per 40 examinations performed using first and second generation of dual-source systems. Examinations were obtained in single-source single-energy and dual-source dual-energy regimens in thoracic or abdominal regions including the protocols containing iterative data reconstruction using algorithm sonogram affirmed reconstruction (SAFIRE). Results. Using the t-test for independent data samples was confirmed, that the effective dose obtained with DECT regimen does not differ from those obtained in single-source-single-energy regimen, even if both using SAFÍRE algorithm (p = 0.0299; 0.9337; 0.8207), but on the other side the significant diference occured between DECT with and without iterative reconstruction (p < 0.0001 in all). Conclusion. The iterative reconstruction enables the significant reduction of the effective dose in DECT to the doses equivalent to single-source sytems., and Jiří Ferda, Jan Baxa, Hynek Mírka, Boris Kreuzberg
Autoři prezentují formou kazuistického sdělení případ 57leté ženy s velmi vzácným extragenitálně lokalizovaným maligním Mülleriánským karcinosarkomem retroperitonea infiltrujícím dolní dutou žílu. Je popsána resekce tumoru s částí stěny duté žíly i resekce metastázy v oblasti pánve. Dále autoři diskutují možnosti diagnostiky rozsevu tohoto typu nádoru a doporučenou adjuvantní onkologickou terapii., The authors present the case of a 57-year-old woman with a very rare extragenital malignant retroperitoneal Müllerian carcinosarcoma invading the inferior vena cava. Tumor resection with partial resection of the vena cava wall and resection of metastases in the pelvic area is described. The authors further discuss diagnostic options of metastases of this tumour and the recommended adjuvant chemotherapy., and J. Moláček, J. Brůha, J. Baxa, V. Opatrný, V. Třeška
Autoři prezentují kazuistiku 3leté holčičky, u které byla pomocí zobrazovacích metod (USG a CT) prokázána přítomnost střevního parazita (škrkavka dětská, Ascaris lumbricoides) v tenkém střevě komplikovaná vícečetnou intermitentní intususcepcí., The authors present a case report of a 3-year-old girl, with proving presence of intestinal parasites (roundworm, Ascaris lumbricoides) in the small intestine complicated brains of intermittent intussusception. Ultrasound and CT were major diagnostic tools in this case., Jan Baxa, Jana Cibulková, Renata Vondráková, Boris Kreuzberg, Jiří Ferda, and Literatura
Cíl: Prospektivní sledování pacientů po prodělané akutní myokarditidě s cílem posoudit přínos a bezpečnosti pravidelného sledování pacientů pomocí magnetické rezonance (MR), laboratorních hodnot kardiospecifických enzymů a bicyklové ergometrie s ohledem na možné zkrácení doporučovaného přísného klidového režimu. Metodika: U 21 pacientů s diagnostikovanou akutní myokarditidou (včetně přítomnosti pozdního sycení - LGE při vstupní MR) byla v intervalu 1 a 6 měsíců provedena kontrolní MR, stanovení hladiny hypersenzitivního troponinu I (hs-Tn) a bicyklová ergometrie. Obrazová analýza byla zaměřena na vývoj rozsahu a intenzity LGE lézí v MR, výsledky byly porovnány s vývojem hs-Tn a výsledku bicyklové ergometrie po 1 měsíci. Výsledky: Předběžné výsledky studie prokázaly, že u všech pacientů byla prokázána regrese rozsahu i intenzity LGE při kontrolních vyšetřeních a zároveň nebyl prokázán rozvoj systolické dysfunkce levé komory srdeční u žádného pacienta. Tento vývoj korespondoval s vývojem průměrné hodnoty hs-Tn (z 9214,2 µg/1 na 25,4 µg/1). Při bicyklové ergometru nebyly prokázány závažné arytmie a všichni pacienti prokázali dobrou toleranci fyzické zátěže (minimálně 150 W). Závěr: Předběžné výsledky naší studie ukazují, že kombinace magnetické rezonance, hodnoty hs-Tn a bicyklové ergometrie je bezpečná a přínosná pro sledování pacientů po prodělané akutní myokarditidě. Důkladná analýza provedených výše uvedených vyšetření v delších intervalech je nezbytná pro možnou stratifikaci rizika u pacientů i s ohledem na délku doporučeného klidového režimu., Aim: Prospective study of patients following an acute myocarditis in order to assess the benefits and safety of regular monitoring using MRI, laboratory values of cardiac enzymes and exercise ECG. Methods: 21 patients with acute myocarditis (diagnosis including the presence of late gadolinium enhancement - LGE at acute MR) underwent in 1 and 6 months interval a follow-up MRI, level of hypersensitive tro-ponin I (hs-Tn) and the exercise ECG. Image analysis was focused on the development of LGE extent and intensity, results were compared with the development of hs-Tn and exercise ECG in 1 month follow-up. Results: Preliminary results of the study prove regression of the extent and intensity of LGE in all patients and normal left ventricular systolic function in all patients in 1 and 6 months follow-up. This trend corresponds with the development of the average value of hs-Tn (from 9214.2 µg/1 to 25.4 µg/1). During exercise ECG severe arrhythmia was not identified and all patients showed good tolerance of physical burden (at least 150 W). Conclusion: Preliminary results of our study indicate that the combination of MR, the value of hs-Tn and exercise ECG is safe and beneficial for follow-up of patients after acute myocarditis. A thorough analysis at longer intervals is necessary for possible risk stratification of patients with regard to the duration of recommended rest interval duration., Jakub Šedivý, Jan Baxa, Milan Hromádka, Táňa Matoušková, Richard Rokyta, Jiří Ferda, and Literatura
Cíl. Zhodnotit častost indikací zobrazení srdce a věnčitých tepen pomocí CT, MRI, PET a SPECT na jednom pracovišti. Metoda. Byla provedena retrospektivní analýza indikací neinvazivních zobrazovacích metod srdce na jednom pracovišti, které sdružuje pracoviště radiologická a pracoviště nukleární medicíny. Zhodnoceny byl jednak indikace, jednak absolutní poměr prováděných vyšetření. Výsledky. Nejčastěji prováděnou metodou je SPECT myokardu, která tvoří více než 64 % všech provedených vyšetření, CT tvoří méně než jednu čtvrtinu vyšetření, magnetická rezonance tvoří méně než 7 % vyšetření a PET méně než 1 %. Nejvýznamnějšími indikacemi je ischemická choroba srdeční, která zcela převládá v indikacích, a to nejen z důvodu velkého zastoupení SPECT vyšetření, ale i díky indikacím k CT. U vyšetření magnetické rezonance dominovaly indikace při podezření na myokarditidu. Závěr. Vyšetření srdce tvoří významnou část vyšetření prováděných na radiologicko-nukleárně-medicínském pracovišti. Počty vyšetření v souhrnu převyšují ve srovnatelných časových úsecích počet katetrizačních výkonů na srdci a věnčitých tepnách., Aim. To evaluate the indications in cardiac imaging using CT, MRI, PET and SPECT performed in one department. Methods. The retrospective analysis of the indications in cardiac imaging in one performing department including radiology and nuclear medicine was done. The proper indications with the particular ratio of imaging methods such as CT, MRI, SPECT and PET were assessed. Results. Myocardial SPECT is the most frequent imaging modality of the heart, it forms more than 64% of all procedures; CT examinations count less than one quarter of imaging procedures, MRI less than 7% and PET less than 1%. The most important indication is the ischemic heart disease due to the leading number of SPECTs, also due to the indications of CT of the heart. The suspected myocarditis is the leading indication of MRI procedures. Conclusion. The heart imaging is the important part of all procedures performed in department including both radiology and nuclear medicine. The number of all no-invasive procedures exceeds the number of catheter-based examinations in interventional cardiology., Jiří Ferda, Jan Baxa, Eva Ferdová, Alexander Malán, Jan Záhlava, Lucie Baxová, and Literatura 19
Cíl: Posoudit vlastní zkušenosti s prováděním PET/CT s fluorocholinem (18F-FCH-PET/CT) u karcinomu prostaty. Metodika: Byla provedena analýza indikací a výsledků 172 vyšetření 18F-FCH-PET/ CT u 139 mužů, průměrný věk nemocných byl 62,5 v rozpětí 48-81 let. Věnovali jsme se výskytu metastáz, vztahu hladiny PSA u biochemického relaps a přítomnosti nádorové tkáně po radikální léčbě a také porovnání bi-optického nálezu s nálezem PET/CT. Výsledky: U nemocných s hladinou PSA 2-5 ng/1 jsme nalezli metastázy nebo lokální rekurenci v 77,4 %, u hladin nad 5 ng/1 ve 100 %. Při porovnání nálezů biopsie s nálezy PET/CT jsme dosáhli senzitivity 96 %, specificity 83,3 %. Závěr: 18F-FCH-PET/CT je, jak ukazují naše výsledky, efektivním nástrojem v posuzování stagingu i restagingu karcinomu prostaty., Aim: To evaluate our own experience with fluorocholine 18F-FCH-PET/CT in prostatic carcinoma. Method: the analysis of the indications was performed in sample of 172 18F-FCH-PET/CT in 139 male patients, with mean age of 62.5 years in range 48-81 years. We evaluated number and site of metastases, the relation of PSA level in biochemical relaps with the presence of FCH accumulation in tumorous tissue and finally we correlate the findings of biopsy with results of PET/CT. Results: IN patients with PSA level 2-5 ng/1 we found in cases of biochemical relapse the accumulating tumorous tissue of local recurrence or metastases in 77.4%, in those patients with PSA level above 5 ng/1 in 100% of cases. In comparison of biopsies with PET/CT we found sensitivity 96% and specificity 83.3%. Conclusion: 18F-FCH-PET/CT is a valuable tool in evaluation of staging or restaging in patients with prostatic carcinoma., Eva Ferdová, Jiří Ferda, Jan Baxa, Milan Hora, Ondřej Hes, Jindřich Fínek, and Literatura