Optimisation of water treatment conditions with usage of aluminium sulphate and ferric sulphate was made with raw water containing high concentrations of natural aluminium. For optimisation of coagulation conditions here were used the jar tests. The efficiency of aggregation was evaluated with the help of the degree and test of aggregation. In all water samples used, the total aluminium concentration was fractionated into nine forms. The high values of degree of aggregation and high portion of macro-, micro-, and primary particles were attained in optimally treated water samples using both types of coagulants. It contrasts to the portion of nonaggregated particles ranging in optimal treated water only from 3% to 7%. Fractionation of total aluminium proved that the removal efficiency of all Al fractions is very good. and V této práci byly optimalizovány podmínky úpravy vod s přirozeně zvýšeným obsahem hliníku. K optimalizačním testům byla použita sklenicová zkouška. Výsledky byly hodnoceny pomocí testů agregace a stupně agregace. Dále byly u všech vzorků surových i upravených vod provedeny frakcionace celkového hliníku. Výsledky ukázaly, že při optimálních dávkách obou použitých koagulačních činidel je dosahováno vysoké účinnosti agregace. V upravené vodě byly nejvíce zastoupeny mikročástice, makročástice a primární částice hliníku, naopak neagregovaný podíl koagulačního činidla tvořil pouze 3 až 7 %. Při použití obou koagulačních činidel byla zjištěna vysoká účinnost odstranění jednotlivých frakcí hliníku.