This work discusses the clinical performance of deconjugated metanephrine (MN), normetanephrine (NMN) and 3-methoxytyramine (3MT) determined in the basal first morning urine using a chromatographic method with electrochemical detection for the clinical diagnosis of pheochromocytoma (PHEO) and paraganglioma (PGL). Urine samples were collected from 44 patients (36 with PHEO, 8 with PGL) aged 54+/-17 (20-78) years (22 females, 22 males). A sampling of biological materials was performed preoperatively and about one week, six months and one year after adrenal gland surgery. The control group consisted of 34 PHEO/PGL patients more than 4 months after adrenal gland surgery. All subjects in the control group were without a diagnosis of PHEO or PGL. Clinical sensitivity was 55 % for MN, 64 % for NMN, 80 % for combination of both MN and NMN, and only 23 % for 3TM. Clinical specificity calculated from the control group was 93 % for MN, 95 % for NMN, 95 % for the combination MN and NMN, and 97 % for 3TM. Cut-off values for deconjugated metanephrines in the basal urine were 310 (MN), 690 (NMN) and 250 μg/l (3MT). Chromatographic determination of deconjugated urinary metanephrines, which is simple without the necessity of special laboratory material, can serve for the screening of PHEO or PGL patients. Urine NMN and 3MT exerts an association to malignity, and all markers are associated with tumor mass. However, the principal laboratory diagnosis of PHEO or PGL must be based on plasma-free metanephrines and plasma chromogranin A with better performance in the laboratory diagnosis of PHEO or PGL., R. Bílek, T. Zelinka, P. Vlček, J. Dušková, D. Michalský, K. novák, J. Bešťák, J. Widimský Jr., and Obsahuje bibliografii
Hyperhomocysteinemia has been suggested to induce hypertension due to its role in endothelial dysfunction. However, it remains controversial whether homocysteine and hypertension are truly causally related or merely loosely associated. To test the hypothesis that hyperhomocysteinemia occurs in spontaneously hypertensive rats (SHR) we measured plasma levels of homocysteine in 10 male adult SHR and in 10 normotensive controls using ion exchange chromatography. In addition, plasma concentrations of the 22 most common amino acids were measured to explore the relation of homocysteine with amino acid metabolism. Plasma levels of homocysteine were significantly lower in SHR (4.1±0.1 μmol/l) than in controls (7.2±0.3 μmol/l) (p<0.00001). The amounts of aminobutyric acid, alanine, citrulline and valine were also decreased, whereas we found increased levels of aspartate, glutamate, glutamine, histidine and ornithine. Thus, contrary to our hypothesis, hypertension in SHR occurs despite low plasma levels of homocysteine. We provide a new hypothesis whereby reduced conversion of arginine to citrulline is related to increased ornithine levels, but decreased bioavailability of nitric oxide, resulting in impaired blood vessel relaxation and hypertension. In conclusion, our findings do not necessarily exclude that homocysteine and hypertension might be pathophysiologically connected, but corroborate the notion that hypertension can arise due to mechanisms independent of high homocysteine levels., D. Kondziella, H. Zetterberg, E. Haugen, M. Fu., and Obsahuje bibliografii a bibliografické odkazy
Úvod: Prvním neutrálním lipofilním techneciovým komplexem schopným projít hematoencefalickou bariérou byl [99mTc]technecium-exametazim. Dalším takovým komplexem používaným v klinické praxi je [99mTc]technecium-bicisát. Obě radiofarmaka se připravují značením kitů různých výrobců, které se liší svými parametry srovnávanými v této práci. Metoda: Porovnání parametrů kitů uvedených v souhrnech údajů o přípravcích (SPC), stanovení radiochemické čistoty (RCP), konzultace zobrazovací schopnosti s lékařem. Výsledky: Parametry kitů pro [99mTc]technecium-exametazim: BRAIN-SPECT KIT, NEUROSCAN, STABILISED CERETEC a [99mTc]technecium-bicisát: NEUROLITE jsou podle uvedeného pořadí následující: objem pro přípravu: 5 ml, 5 ml, 7 ml, 4 ml; max. aktivita: 2,22 GBq, 1 GBq, 1,11 GBq, 3,7 GBq; možnost ředění: ano, ano, ano, ne; objem lahvičky: 9 ml, 10 ml, 11 ml, 5 ml; stabilita kitu před a po označení: 1 r / 1 h, 1 r / 0,5 h, 1 r / 5 h, 1,5 r / 8 h; dosahovaná RCP / obsah volného technecistanu v %: 87,8 ± 0,6 / 5,9 ± 1,4, 86,6 ± 2,8 / 4,0 ± 2,7, 91,6 ± 0,9 / 1,9 ± 0,4, 97,2 ± 0,7 / nestanovuje se; zobrazovací schopnost všech kitů srovnatelná; zaregistrované indikace obdobné. Závěr: Hlavními výhodami [99mTc]-bicisátu (NEUROLITE) oproti [99mTc]-exametazimu (ostatní kity) jsou nejlepší stabilita, které nedosahuje ani STABILISED CERETEC a použití [99mTc]eluátu bez zvláštních omezení. Není však vhodný pro značení leukocytů. Z kitů pro [99mTc]-exametazim je největší výhodou STABILISED CERETECu jeho dlouhá stabilita a BRAIN-SPECT KITu nejvyšší aktivita. Výhodné je použití kitů s dlouhou stabilitou (NEUROLITE, STABILISED CERETEC) dosahujících nejvyšší RCP a tím i nejvyšší relativní biologické dostupnosti pro mozek., x, Jiří Štěpán, and Literatura