1 - 4 of 4
Number of results to display per page
Search Results
2. Myeloperoxidáza
- Creator:
- Jabor, Antonín and Franeková, Janka
- Type:
- model:article, article, Text, úvodníky, and TEXT
- Subject:
- peroxidasa--analýza, prediktivní hodnota testů, biologické markery--krev, akutní koronární syndrom--diagnóza, klinické laboratorní techniky, reagenční soupravy diagnostické, and kongresy jako téma
- Language:
- Czech
- Description:
- Antonín Jabor, Janka Franeková
- Rights:
- http://creativecommons.org/publicdomain/mark/1.0/ and policy:public
3. Průkaz makro AST v běžné klinické praxi
- Creator:
- Komrsková, Jitka, Hejlová, Irena, Kubíček, Zdeněk, Bartošová, Kamila, Jabor, Antonín, and Franeková, Janka
- Format:
- electronic, electronic resource, and remote
- Type:
- model:article, article, Text, and TEXT
- Language:
- Czech and English
- Description:
- Typ studie: původní práce Název a sídlo pracoviště: Institut klinické a experimentální medicíny, Vídeňská 1958/9, 140 21 Praha 4 Materiál a metody: Precipitace pacientského séra s polyethylenglykolem 6000 (PEG 6000, Sigma Aldrich) v objemovém poměru 1:1, centrifugace, následné stanovení aktivity enzymu AST v supernatantu na analyzátoru Architect ci16200 firmy Abbott a porovnání získané hodnoty aktivity AST s hodnotou v pacientském séru naředěném fyziologickým roztokem v objemovém poměru 1:1. Porovnání vzorků testovaných pacientů s dvěma kontrolními vzorky se zvýšenou aktivitou AST bylo hodnoceno na základě výpočtu procenta precipitační aktivity polyethylenglykolu (PEG-precipitable activity, % PPA) dle Davidsona a Watsona. Séra pacientů a kontrol byla dále skladována při 4°C po dobu 144 hodin a monitorování aktivity enzymu AST bylo prováděno každých 24 hodin. Výsledky a závěr: U obou vyšetřovaných pacientů bylo po precipitaci s PEG 6000 potvrzeno podezření na výskyt makroenzymové formy AST v séru (% PPA 92 a 79), na rozdíl od techniky skladování vzorku při 4°C, kde pokles aktivity AST nebyl prokázán. Použití poměrně jednoduchého a finančně nenáročného laboratorního průkazu makroenzymové formy AST mohou zamezit dalším nákladným invazivním vyšetřením a diagnostickým chybám., Design: Original paper Settings: Institute of Clinical and Experimental Medicine, Vídeňská 1958/9, 140 21 Praha 4 Materials and Methods: Sera of two tested patients were precipitated with polyethylene glycol 6000 (PEG 6000, Sigma Aldrich) in a volume ratio of 1:1. After centrifugation, AST enzyme activity in the supernatant was determined (Architect ci16200, Abbott). AST enzyme activity values were compared to those of the patient sera, which were diluted with saline (NaCl 9 g/L) in a volume ratio of 1:1. The results of comparing of the tested patient samples with the two control samples were evaluated as a percentage of PEG-precipitable activity (%PPA). The patient and control sera were stored at 4°C for 144 hours and AST enzyme activity was monitored after each 24 hours. Results and Conclusions: The presence of macro-AST as the most probable cause of permanently increased activity of AST in serum was confirmed. PEG-precipitable activities in tested patients were 92 and 79 %, respectively. In contrast, the comparative method of storing samples at 4°C did not reveal any decline of AST activity. These relatively simple and inexpensive laboratory methods of macro-AST detection can save on unnecessary examinations as well as prevent diagnostic errors., Komrsková J., Hejlová I., Kubíček Z., Bartošová K., Jabor A., Franeková J., and Literatura
- Rights:
- http://creativecommons.org/publicdomain/mark/1.0/ and policy:public
4. Společné doporučení České společnosti klinické biochemie ČLS JEP a České společnosti pro aterosklerózu ČLS JEP ke sjednocení hodnoticích mezí krevních lipidů a lipoproteinů pro dospělou populaci
- Creator:
- Soška, Vladimír, Zima, Tomáš, Friedecký, Bedřich, Franeková, Janka, Buryška, Jan, Palička, Vladimír, Jabor, Antonín, Poledne, Rudolf, Freiberger, Tomáš, Piťha, Jan, Štulc, Tomáš, Urbanová, Zuzana, Vaverková, Helena, Vrablík, Michal, Češka, Richard, and Rosolová, Hana
- Type:
- model:article, article, Text, směrnice pro lékařskou praxi, and TEXT
- Subject:
- lipoproteiny--krev--normy, lipidy--krev--normy, referenční hodnoty, lidé, and dospělí
- Language:
- Czech
- Description:
- Soška V., Zima T., Friedecký B., Franeková J., Buryška J., Palička V., Jabor A., Poledne R., Freiberger T., Piťha J., Rosolová H., Štulc T., Urbanová Z., Vaverková H., Vrablík M., Češka R. and Lit.: 8
- Rights:
- http://creativecommons.org/publicdomain/mark/1.0/ and policy:public