The article deals with axial-symmetric subsonic air-to air ejector with a diffuser adapted for boundary layer suction. The diffuser, which is placed after the mixing chamber of the ejector, has a high divergence angle and is therefore inefficient. To increase efficiency, the diffuser is equipped with a slot enabling boundary layer suction. The effect of boundary layer suction on the airflow in the ejector was measured, as were the static pressure distribution on the mixing chamber wall and ejector characteristics. Both diffuser and ejector efficiency were calculated. Although the efficiency of the diffuser was increased, the efficiency of the ejector itself remained low. and Obsahuje seznam literatury
This work with numerical and experimental studies of specific issues of natural convection flow around a horizontal cylinder in a space limited by rectangular cavity. Physical models of laminar unsteady flows have been used for numerical calculations of heat transfer coefficients of four different diameters of horizontal cylinders and for several temperature gradients. Procedures and results of the experimental studies are contained in the next section. All results were compared with different authors and different approaches, However the Nusselt numbers can be estimated due to the temperature interval, the results indicate need for further investigation. and Obsahuje seznam literatury