The paper describes results of validation of authors' recently proposed formulae for sediment transport and bed friction in the upper plane bed regime using laboratory experiments in a pressurized pipe. Flows of mixture of water and fine to medium ballotini (d50 = 0.18 mm) were observed in a rectangular pipe (51 x 51 mm) with a deposit at the bottom of the pipe. A comparison of test results with transport-formula predictions shows a satisfactory match confirming a good prediction ability of the proposed transport formula at high bed shear. A prediction ability of the friction formulae appears to be less convincing but still reasonable. A joint use of the formulae for transport and friction predicts the delivered concentration of transported sediment within the accuracy range of ± 40 per cent for flows in which transported sediments strongly affect the bed friction, i.e. for flows with delivered concentration of sediment higher than say 3 per cent.