A comparison of different rubber dam systems on a dental simulator
- Title:
- A comparison of different rubber dam systems on a dental simulator
A comparison of different rubber dam systems on a dental simulator - Creator:
- Kapitán, Martin, Šustová, Zdeňka, Koberová Ivančaková, Romana, and Suchánek, Jakub
- Contributor:
- Kapitán, Martin , 1984-, Šustová, Zdeňka , 1951-, Koberová Ivančaková, Romana , 1964-, and Suchánek, Jakub , 1981-
- Identifier:
- https://cdk.lib.cas.cz/client/handle/uuid:bmc14071294-cc4f5285-7b24-45cd-adb7-e7ac0122da03
uuid:bmc14071294-cc4f5285-7b24-45cd-adb7-e7ac0122da03
local:bmc14071294
https://www.lfhk.cuni.cz/Faculty/Publications/Acta-Medica/Archive/2014/Acta-Medica-2014-Vol-57-No-1/
local: bmc14071294 - Subject:
- design vybavení, lidé, testování materiálů, biologické modely, and gumové blány
- Type:
- model:article, article, Text, srovnávací studie, časopisecké články, práce podpořená grantem, and TEXT
- Format:
- print, text, and regular print
- Description:
- The purpose of this study was to test the hypothesis that more recently developed rubber dam systems (OptraDam ® Plus and OptiDam™) are faster and easier to handle, and that the quality of isolation is not decreased. The rubber dam systems were applied in standard conditions on a dental simulator in several model clinical situations. The time of preparation, application and removal were measured and the quality of isolation was evaluated. The median time of rubber dam placement was 51 s (Q1 = 38 s; Q3 = 79 s). The shortest median time of application was with OptiDam™ (42 s), followed by a conventional rubber dam (53 s), and finally the longest was with OptraDam® Plus (58 s). The median volume of fluid remaining in the isolated space after 5 minutes was 9.5 mL (Q1 = 8 mL; Q3 = 10 mL). The largest median volume of remaining water was with OptiDam™ (10 mL), followed by a conventional rubber dam (9.5 mL) and the least with OptraDam® Plus (8.5 mL). The afore-stated hypothesis about the advantages of modern rubber dam isolation systems was accepted for OptiDam™, but rejected for OptraDam® Plus. The results could contribute to decision-making concerning the choice of rubber dam system. and Martin Kapitán, Zdeňka Šustová, Romana Ivančaková, Jakub Suchánek
- Language:
- English
- Rights:
- http://creativecommons.org/publicdomain/mark/1.0/
policy:public - Relation:
- Acta medica (Hradec Králové) / Universitas Carolina, Facultas Medica Hradec Králové--MED00010947
- Source:
- Acta medica (Hradec Králové) | 2014 Volume:57 | Number:1
- Harvested from:
- CDK
- Metadata only:
- false
- Date:
- 2014
The item or associated files might be "in copyright"; review the provided rights metadata:
- http://creativecommons.org/publicdomain/mark/1.0/
- policy:public