Multikapilární elektroforetické systémy Paragon 2000 a Capillarys 2 v rutinní praxi
- Title:
- Multikapilární elektroforetické systémy Paragon 2000 a Capillarys 2 v rutinní praxi
Multikapilární elektroforetické systémy Paragon 2000 a Capillarys 2 v rutinní praxi : Multicapillary electrophoretic systems Paragon 2000 and Capillarys 2 in routine practice
Multicapillary electrophoretic systems Paragon 2000 and Capillarys 2 in routine practice - Creator:
- Vávrová, Jaroslava, Friedecký, Bedřich, and Tichý, M.
- Contributor:
- Vávrová, Jaroslava , 1958-, Friedecký, Bedřich , 1941-, and Tichý, M.
- Identifier:
- https://cdk.lib.cas.cz/client/handle/uuid:bmc08001983-ee6caac9-a9d1-4b4a-8102-b101d3119336
uuid:bmc08001983-ee6caac9-a9d1-4b4a-8102-b101d3119336
local:bmc08001983
local: bmc08001983 - Subject:
- elektroforéza kapilární--metody--přístrojové vybavení and elektroforéza proteinů krevního séra--přístrojové vybavení
- Type:
- model:article, article, Text, and TEXT
- Description:
- Kapilární elektroforéza (CZE) je alternativní metodou separace a semikvantitativního hodnocení sérových proteinů. Krátké sdělení se zabývá rutinním použitím multikapilárních systémů pro elektroforézu sérových bílkovin a dopadem výměny přístroje Paragon 2000 (Beckman-Coulter) za Capillarys 2 (Sebia) provázené změnou referenčních mezí. Dlouhodobé sledování cyklů externího hodnocení kvality dokládá plynulý přechod a srovnatelnost od elektroforézy na agarózovém nosiči k multikapilárním systémům. Výsledky jsou mezilaboratorně dobře srovnatelné, lze rovněž vyvodit závěr, že změny analytického systému pro rutinní elektroforézu sérových bílkovin v časovém intervalu dvou let nepřinesly komplikace ani v oblasti kvantitativního hodnocení gamapatií., Capillary zone electrophoresis (CZE) is an alternative method for the separation and quantitative evaluation of serum proteins. CZE is very effective, quick and namely a precise method. Two specific automated multichannel (multicapillary) instruments are available, the Paragon 2000 (Beckman-Coulter) and the Capillarys 2 (Sebia), characterized by different number of assessed protein fractions are mentioned and newly tested reference intervals. Long-term observation of the cycles of external quality assurance (EQA) programs exemplifies smooth transition from agarose electrophoresis to multichannel capillary systems and comparability of analysis. The interlaboratory comparisons indicated good comparability of the results and conclusion may therefore be drawn that the changes in analytical systems for routine electrophoresis of serum proteins within the time interval of two years have not complicated the situation in the area of quantitative evaluation of gammapathies as well., Jaroslava Vávrová, Bedřich Friedecký, M. Tichý, and Lit. 4
- Language:
- Czech and English
- Rights:
- http://creativecommons.org/publicdomain/mark/1.0/
policy:public - Relation:
- Klinická biochemie a metabolismus--MED00011026
- Source:
- Klinická biochemie a metabolismus : časopis České společnosti klinické biochemie | 2007 Volume:15 | Number:2
- Harvested from:
- CDK
- Metadata only:
- false
- Date:
- 2007
The item or associated files might be "in copyright"; review the provided rights metadata:
- http://creativecommons.org/publicdomain/mark/1.0/
- policy:public