Hemodynamic response to thoracoscopy and thoracotomy
- Title:
- Hemodynamic response to thoracoscopy and thoracotomy
- Creator:
- Trča, S., Zdeněk Krška, Otomar Kittnar, Mikuláš Mlček, Rudolf Demeš, Vilém Danzig, Stanislav Šimek, Jan Bruthans, and Roman Fraško
- Identifier:
- https://cdk.lib.cas.cz/client/handle/uuid:1a32d3c3-a1b1-4f56-8e32-d554f42f68dc
uuid:1a32d3c3-a1b1-4f56-8e32-d554f42f68dc - Subject:
- Fyziologie člověka a srovnávací fyziologie, hemodynamika, plicní oběh, hemodynamics, pulmonary circulation, thoracoscopy, thoracotomy, 14, and 612
- Type:
- article, články, model:article, and TEXT
- Format:
- Description:
- Operations in the pleural cavity are connected with circulatory changes in pulmonary circulation and general changes of hemodynamics. These changes are influenced by the position of patient’s body on the operation table and by the introduction of artificial pneumothorax. Thoracoscopy is an advanced surgical approach in thoracic surgery, but its hemodynamic effect is still not known. The aim of the present study was to compare the hemodynamic response to surgeries carried out by open (thoracotomy - TT) and closed (thoracoscopy - TS) surgical approach. Thirty-eight patients have been monitored throughout the operation - from the introduction of anesthesia to completing the surgery. Monitored parameters were systolic blood pressure (BPs), diastolic blood pressure (BPd), O2 saturation (SaO2), systolic blood pressure in pulmonary artery (BPPAs), diastolic blood pressure in pulmonary artery (BPPAd), wedge pressure (PW), central venous pressure in right atrium (CVP), cardiac output (CO) and total peripheral resistance (TPR). No significant difference has been found in hemodynamic response between TT and TS groups. Significant changes of hemodynamic parameters occurring during the whole surgical procedure were detected in both technical approaches. The most prominent changes were found after the position of patients was changed to the hip position (significantly decreased BPs, BPd, MAP, SaO2 and BPPAs) and 5 min after the pneumothorax was established (restoration of the cardiac output to the initial value and significant decrease of the TPR). It can be concluded that the thoracoscopy causes almost identical hemodynamic changes like the thoracotomy., S. Trča ... [et al.]., and Obsahuje bibliografii a bibliografické odkazy
- Language:
- English
- Rights:
- http://creativecommons.org/licenses/by-nc-sa/4.0/
policy:public - Source:
- Physiological research | 2010 Volume:59 | Number:3
- Harvested from:
- CDK
- Metadata only:
- false
The item or associated files might be "in copyright"; review the provided rights metadata:
- http://creativecommons.org/licenses/by-nc-sa/4.0/
- policy:public