For borescopes presented in papers [1] and [2] there can be sometimes advantageous to introduce an optical splitter, especially when we consider a regulation of the flame also in the near infrared (NIR) spectral region, see [3]. A conventional circular double-wedge plate with metal coated frontal surface of intensity ratio R/T = 80/20 allows to complete suppression of parasitic images from multiple reflected beams. The reflected beam serves for self-monitoring and regulation of the thermal efficiency of the flame during the combustion process and can be used also for monitoring in the NIR. Direct beam, which normally is designed for observation of the burning process can be further splitted electronically and used for regulation in visible light (VIS) region and direct observation of the flame. By the appropriate adaptation of brightness of computer monitor the residual intensity of the parasitic direct image can be handled. and U typů boroskopů, prezentovaných v článcích [1] a [2], je někdy výhodné zavést optický dělič, zvláště pak v tom případě, jestliže uvažujeme regulaci plamene i pro oblast blízkého infračerveného záření (NIR), viz [3]. Klasické uložení kruhového dvojklínu s napařenou kovovou frontální plochou s poměrem intenzit R/T = 80/20 umožňuje úplné potlačení parazitního obrazu v odraženém svazku, který slouží k vlastnímu monitorování nebo regulaci tepelné účinnosti plamene během spalovacího procesu, případně monitorování v oblasti NIR. Svazek přímý, který je běžně určen pro pozorování hořícího procesu, může být dále dělen elektronicky, případně využit pro regulaci ve viditelném světle (VIS), přičemž vhodným přizpůsobením jasu obrazovky počítače je možno ovlivnit zbytkovou intenzitu parazitního přímého obrazu.