Paper is devoted to magneto-optical (MO) methods, which are frequently used for investigation of surface magnetic properties of magnetic nanostructures. We describe two MO set-ups that are recently built in scientific laboratories of institute of Physics VŠb-TU Ostrava. Differential MO method based on the surface hysteresis loop measurements enables to obtain separate components of magnetization vector M and to study the anisotropy of magnetic systems. basic element of the second set-up is the MO kerr microscope, which serves for the magnetic domains and domain wall observations. both mentioned methods in combination with other magnetic measurements (X-ray diffraction, conversion electron Mössbauer spectroscopy) are used to investigate soft magnetic properties of as-quenched and annealed Fenbb ribbons. and Článek je věnován magnetooptickým (MO) metodám, které jsou často využívány ke studiu povrchových vlastností magnetických nanostruktur. Jsou zde detailně popsány dvě aparatury, které jsou v současné době sestaveny ve výzkumných laboratořích Institutu fyziky VŠB-TU Ostrava. Diferenciální MO metoda založená na měření povrchových hysterézních smyček umožňuje určit jednotlivé komponenty vektoru magnetizace M a studovat anizotropii magnetických systémů. Základním prvkem druhé aparatury je MO Kerrův mikroskop, který slouží k pozorování magnetických domén a doménových stěn na povrchu nanostruktur. Obě MO metody v kombinaci s dalšími magnetickými měřeními (X-ray difrakce, konverzní elektronová Mössbauerova spektroskopie) jsou využity k výzkumu měkkých magnetických vlastností nežíhaných a žíhaných FeNbB pásků.